Sysmex CA-600 / CS-2500 / CN-3000 Bi-Directional LIS Interfacing Guide

Complete engineering specification, HL7/ASTM protocols, pinouts, and parameter mapping for Sysmex CA-600 / CS-2500 / CN-3000 on AILS Cloud LIMS.

Sysmex CA-600 / CS-2500 / CN-3000 Analyzer - AILS LIS Interfacing Guide
Manufacturer
Sysmex
Protocol
ASTM E1394 / HL7
Interface Mode
Bi-Directional
Throughput
60 - 180 tests/hour

1. Sysmex CA-600 / CS-2500 / CN-3000 Interfacing Overview & Diagnostic Workflow

The Sysmex CA-600 / CS-2500 / CN-3000 is a precision diagnostic analyzer designed for clinical laboratory testing. Connecting the Sysmex CA-600 / CS-2500 / CN-3000 directly to AILS Cloud LIMS eliminates manual data entry, prevents typographical identification errors, and delivers verified results directly to ordering physicians and hospital EMRs.

Bi-Directional Order Interfacing

AILS Gateway manages bi-directional ASTM E1394 / HL7 worklist handshakes with the Sysmex CA-600 / CS-2500 / CN-3000, streaming patient test requests as samples are loaded.

Quality Control & Reference Range Interlock

Results are checked against age- and gender-adjusted reference ranges, delta check baselines, and quality control (QC) Levey-Jennings rules before digital sign-off.

2. Sysmex CA-600 / CS-2500 / CN-3000 RS-232 Serial Port & Pinout Configuration

Hardware & Socket Configuration

TCP/IP Ethernet (Port 5001) / RS-232 DB9 Serial Cable (9600 Baud, 8-N-1).

Protocol: ASTM E1394 / HL7
Interface Mode: Bi-Directional
Default Speed: 9600 / TCP 5001
// RS-232 DB9 NULL-MODEM PINOUT SERIAL COM
[Instrument DB9]                   [AILS Gateway PC]
Pin 2 (TxD / Data Out) ---------> Pin 2 (RxD / Data In)
Pin 3 (RxD / Data In)  <--------- Pin 3 (TxD / Data Out)
Pin 5 (GND / Signal)   <========> Pin 5 (GND / Signal)
Pin 7 (RTS) & Pin 8 (CTS)        [Loopback or None]
Baud: 9600 / TCP 5001 | Data Bits: 8 | Parity: None | Stop: 1
Verified with AILS Gateway Daemon & Real-Time Socket Router.

3. Sysmex CA-600 / CS-2500 / CN-3000 HL7 v2.x Message Stream

Below is a validated communication frame transmitted between the Sysmex CA-600 / CS-2500 / CN-3000 and AILS LIS middleware:

<STX>1H|\^&|||Sysmex CA-600|||||||P|1394-97|20260815164000<CR><ETX>4C<CR><LF>
<STX>2P|1||||Walker^James|||M<CR><ETX>2A<CR><LF>
<STX>3O|1|ACC2026081558||^^^COAG_PANEL|||||||A<CR><ETX>4D<CR><LF>
<STX>4R|1|^^^PT|12.4|sec|11.0-13.5|N||F<CR><ETX>1B<CR><LF>
<STX>5R|2|^^^INR|1.02|Ratio|0.8-1.2|N||F<CR><ETX>2C<CR><LF>
<STX>6R|3|^^^APTT|29.5|sec|25.0-35.0|N||F<CR><ETX>28<CR><LF>
<STX>7R|4|^^^FIB|310.0|mg/dL|200.0-400.0|N||F<CR><ETX>3E<CR><LF>
<STX>8R|5|^^^D_DIMER|0.32|ug/mL|0.0-0.5|N||F<CR><ETX>25<CR><LF>
<STX>9L|1|N<CR><ETX>0A<CR><LF>

4. Sysmex CA-600 / CS-2500 / CN-3000 Clinical Parameter LOINC & Reference Range Dictionary

Instrument Code LOINC Code Clinical Parameter Name Standard Units Default Reference Range
PT 5902-2 Prothrombin Time sec 11.0 - 13.5
INR 6301-6 International Normalized Ratio (INR) Ratio 0.8 - 1.2
APTT 3173-2 Activated Partial Thromboplastin Time sec 25.0 - 35.0
FIB 3255-7 Fibrinogen (Clauss Method) mg/dL 200.0 - 400.0
D_DIMER 48065-7 D-Dimer Quantitative (FEU) ug/mL 0.0 - 0.5

5. Sysmex Biomedical Engineering Field Notes & Gotchas

1

In Sysmex CA/CS setup, configure Host Protocol to ASTM E1394 with Baud Rate 9600 or TCP Port 5001.

2

Verify that ISI (International Sensitivity Index) calibration value is synchronized for accurate INR calculation.

3

Optical reaction curve analysis data (scattered light intensity) can be stored for clot reaction verification.

TECHNICAL FAQ

Frequently Asked Questions: Sysmex CA-600 / CS-2500 / CN-3000 LIS Interfacing

Common biomedical engineering questions regarding connection, worklist setup, and data capture with AILS Cloud LIMS.

Q: What interface protocols are supported by Sysmex CA-600 and CS-2500?

Sysmex CA-600 and CS series coagulation analyzers use ASTM E1381/E1394 standard protocol over RS-232 serial or TCP/IP socket.

Q: How does AILS handle INR calculations from Prothrombin Time results?

AILS verifies the measured PT in seconds against the analyzer's mean normal PT and reagent ISI factor, confirming the transmitted INR value.

Q: How are critical panic values (e.g. INR > 4.5 or Fibrinogen < 100 mg/dL) handled?

Critical coagulation values trigger visual panic alerts on laboratory dashboards and send automated emergency SMS alerts to clinicians.

Q: Can CS-2500 multi-wavelength optical pre-analytical checks (HIL) be captured?

Yes. Pre-analytical sample integrity checks for Hemolysis, Icterus, and Lipemia are logged to assess potential coagulation interference.

Q: What serial cable is required for Sysmex CA-600?

A standard DB9 Female Null Modem serial cable running at 9600 baud, 8 data bits, Parity None, 1 stop bit.

INSTRUMENT DIRECTORY

Related Coagulation Instrument Guides

Compare protocols, pinouts, and parameter mapping dictionaries for comparable diagnostic equipment.

View All 50+ Analyzers
PRE-CONFIGURED DRIVER READY

Connect Your Sysmex CA-600 / CS-2500 / CN-3000 to AILS in Under 15 Minutes

Our specialized biomedical engineering team provides complete plug-and-play drivers, cable diagrams, and bi-directional test verification for the Sysmex CA-600 / CS-2500 / CN-3000.