ABBOTT ANALYZER INTERFACING GUIDE

Abbott Alinity ci-series / i-series Bi-Directional LIS Interfacing Guide

Complete engineering specification, HL7/ASTM protocols, pinouts, and parameter mapping for Abbott Alinity ci-series / i-series on AILS Cloud LIMS.

Abbott Alinity ci-series / i-series Analyzer - AILS LIS Interfacing Guide
Manufacturer
Abbott
Protocol
HL7 v2.5 / ASTM E1394
Interface Mode
Bi-Directional
Throughput
Up to 1,550 tests/hour

1. Instrument Overview & Interfacing Architecture

The Abbott Alinity ci-series / i-series is a high-performance immunoassay instrument designed for diagnostic laboratories and hospital health networks. Integrating this analyzer directly with AILS Cloud LIMS eliminates manual transcription delays, prevents typographical patient identification errors, and automatically enforces Westgard delta check algorithms.

Bi-Directional Order Push

AILS automatically generates worklist queries (QRY^Q02 / ASTM orders) mapped to patient accession barcodes and pushes test instructions directly to the instrument sample tray.

Real-Time Result Ingestion

Raw OBX / Result records are parsed instantly within 200 milliseconds, flagged for abnormal reference ranges, and linked to pathologist digital signature queues.

2. Hardware Connection & Communication Settings

// Physical & Socket Configuration
Gigabit Ethernet RJ45 TCP/IP MLLP Socket (Port 5001).
// Protocol: HL7 v2.5 / ASTM E1394 | Connection Type: Gigabit TCP/IP MLLP Socket

3. Sample Message Wire Frame

Below is a real-world communication frame transmitted between the Abbott Alinity ci-series / i-series and AILS LIS middleware:

MSH|^~\&|ALINITY|Abbott|AILS_LIMS|LAB_MAIN|20260815163000||ORU^R01|MSG009970|P|2.5
PID|1||P982440||Robinson^Claire||19860419|F
OBR|1|ORD982440|ACC2026081556|FERTILITY^Fertility Panel|||20260815162500
OBX|1|NM|LH^Luteinizing Hormone||8.45|mIU/mL|1.9-12.5|N|||F
OBX|2|NM|FSH^Follicle Stimulating Hormone||6.20|mIU/mL|2.5-10.2|N|||F
OBX|3|NM|PROG^Progesterone||12.8|ng/mL|1.8-24.0|N|||F
OBX|4|NM|AMH^Anti-Mullerian Hormone||2.65|ng/mL|1.0-4.0|N|||F

4. Parameter & LOINC Standard Code Mapping

Instrument Code LOINC Code Clinical Parameter Name Standard Units Default Reference Range
LH 83103-2 Luteinizing Hormone (LH) mIU/mL 1.9 - 12.5
FSH 15067-2 Follicle Stimulating Hormone (FSH) mIU/mL 2.5 - 10.2
PROG 2839-9 Progesterone Serum ng/mL 1.8 - 24.0
AMH 67160-2 Anti-Mullerian Hormone (AMH) ng/mL 1.0 - 4.0
ESTRADIOL 2243-4 Estradiol (E2) pg/mL 30.0 - 400.0

5. Biomedical Engineering Tips & Common Gotchas

1

In Alinity system software, configure Host Communication to HL7 v2.5 with MLLP framing.

2

Continuous loading track transmits tube arrival events in real time to query test profiles.

3

Ensure AILS Gateway returns ACK within 150ms to sustain maximum track throughput.

TECHNICAL FAQ

Frequently Asked Questions: Abbott Alinity ci-series / i-series Interfacing

Common biomedical engineering questions regarding connection, worklist setup, and data capture with AILS Cloud LIMS.

Q: What communication protocol is used by Abbott Alinity systems?

Abbott Alinity uses HL7 v2.5 over TCP/IP MLLP socket (Port 5001) or ASTM E1394.

Q: How does Alinity continuous sample loading coordinate with AILS LIMS?

As sample racks move along the Alinity track, barcode scanners query AILS LIMS in real time, routing tubes to chemistry or immunoassay processing modules automatically.

Q: What throughput can be handled over the AILS Alinity gateway?

The gateway handles up to 1,550 tests/hour with sub-200 millisecond message latency.

Q: Are Alinity STAT urgent samples prioritized automatically?

Yes. STAT priority codes in the HL7 order segment cause Alinity to bypass routine rack queues and aspirate the urgent sample immediately.

Q: How does AILS handle Alinity reagent inventory and lot tracking?

Reagent cartridge RFID telemetry, onboard test remaining counts, and expiration dates are synchronized with AILS Inventory module.

PRE-CONFIGURED DRIVER READY

Connect Your Abbott Alinity ci-series / i-series to AILS in Under 15 Minutes

Our specialized biomedical engineering team provides complete plug-and-play drivers, cable diagrams, and bi-directional test verification for the Abbott Alinity ci-series / i-series.